ADHESIVE / BASECOAT
|
BOND TESTS
5.2.1 Adhesive bond strength to concrete substrate when tested in accordance
with Section 6.3 of the CCMC Technical Guide 07240 met the requirements
noted.
| Test Condition |
Test Requirement |
Results |
Pass/Fail |
| Dry states |
N/A |
3.21 MPa |
Pass |
| 2 hours after removal from water
|
>0.1 MPa |
2.62 MPa |
Pass |
| After drying 7 days from removal
from water |
>0.1 MPa |
2.59 MPa |
Pass |
|
5.2.3.1 Bond test of the coating to the
insulation when tested in accordance with Section 6.4 of the CCMC Technical
Guide 07240 met the requirements noted.
| Test Condition (Basecoat)
|
Test Requirement |
Results |
Pass/Fail |
| Dry states |
N/A |
>0.26 MPa |
Pass |
| 2 hours after removal from water
|
>0.1 MPa |
0.13 MPa |
Pass |
| After drying 7 days from removal
from water |
>0.1 MPa |
0.17 MPa |
Pass |
|
WATER ABSORPTION OF COATINGS
| Test Conducted |
Test Requirement |
Results |
| UEAtc directive for EIFS article
3.3.1.2 water absorption of basecoat |
Must not exceed 20% by weight
|
7.1% |
|